• Energy Level VI 18W 12V 1.5A Wall interchangeable Plug AC/DC Adapter

    • [ Model ]£º UT20
    • [ Input ] £º 90-264Vac
    • [ Type ] £º 
    • [ Dimension ] £º82*40*34.3mm
    • [ N.G. ] £º180g
    • [ Packing ] £º 52.8*43.3*25cm

     Model : UT20

     

    Type:interchangeable AC DC power adapter

     

    Input:90-264VAC 50~60HZ

     

    Output:12V 1.5A

     

    Output Efficiency£º18Wmax

     

    Output Voltage Range£º±5%

     

    Average Efficiency£ºMeet energy star level VI

     

    No Load Power Consumption£º0.1W max

     

    Operating Temperature: 0¡æ~ 45¡æ

     

    Storage Temperature:minus20¡æ~ 60¡æ

     

    Storage Humidity: 5% to 95% non condenising

     

    Hi-Pot Withstand: AC 3000V(Min),5mA(Max)

     

    Insulation Resistance Test:DC 500V  100MΩ(Min)

     

    R/S Voltage:2KV~6KV

     

    MTBF£º50,000 Calculated Hours

     

    Test£º100% Aging Test

     

    Protection£º Over voltage, Short circuit, Over temperature, Over current

     

    Prevention£ºStatic,Electric leakage,Lightning stroke,Fireproofing,In-rush

     

    Adapter size£º 82*40*34.3mm

     

    Adapter N.W£º85g

     

    Warranty£º2 years

     

    MOQ:500pieces

     

    Payment terms: T/T,L/C,Western Union

     

    Deliver terms:within 15-25 working days after other confirmation            

     

    Sample lead Time:5 days

  • Energy Level VI 18W 12V 1.5A AC /DC Power Supply

    • [ Model ]£º UT20
    • [ Input ] £º 90-264Vac
    • [ Type ] £º  Wallmount
    • [ Dimension ] £º82*40*34.3mm
    • [ N.G. ] £º85g
    • [ Packing ] £º 52.8*43.3*25cm

     Model : UT20

    Type:Wall Fixed Plug AC DC power adapter

    Input:90-264VAC 50~60HZ

    Output:12V 1.5A

    Output Efficiency£º18Wmax

    Output Voltage Range£º±5%

    Average Efficiency£ºMeet energy star level V (V2.0)

    No Load Power Consumption£º0.1W max

    Operating Temperature: 0¡æ~ 45¡æ

    Storage Temperature:minus20¡æ~ 60¡æ

    Storage Humidity: 5% to 95% non condenising

    Hi-Pot Withstand: AC 3000V(Min),5mA(Max)

    Insulation Resistance Test:DC 500V  100MΩ(Min)

    R/S Voltage:2KV~6KV

    MTBF£º50,000 Calculated Hours

    Test£º100% Aging Test

    Protection£º Over voltage, Short circuit, Over temperature, Over current

    Prevention£ºStatic,Electric leakage,Lightning stroke,Fireproofing,In-rush

    Adapter size£º 82*40*34.3mm

    Adapter N.W£º85g

    Warranty£º2 years

    MOQ:500pieces

    Payment terms: T/T,L/C,Western Union

    Deliver terms:within 15-25 working days after other confirmation            

    Sample lead Time:5 days

     

Home pagePrevious page1Next pageLast page